1-Remove all packing materials and supports from the interior and from underneath your machine.
-
2-For all five machine frame legs, slide a leg extension through the hole of each frame leg. Tighten the nut and washer on either side of the frame to secure each leg extension
-
If transporting or storing your machine, see Safety and Machine Care Sections on User Manual
-
-
-
Level machine before operating. Adjust all five leg extensions with pads or casters, as needed
-
If your machine is not level, using the width adjustment screw can cause frame stress and changes to alignment.
-
-
-
Turn OFF the manual air supply lockout valve before connecting an air supply to your machine
-
The supply must be clean factory air. Air pressure should be set to 80 PSI for most applications with a minimum setting of 65 PSI and a maximum of 100 PSI
-
-
-
The equipment operates on 120 VAC with a full-load amperage of 10 A, and is designed for 1-phase, 60 Hz power. It meets NEMA 12 standards and requires a 3-prong, 14-gauge (AWG) power cord.
-
The control system features a SIEMENS LOGO logic controller with non-contact photo-sensors and solenoid valves running at 24 VDC. The conveyor drive is powered by a 1/2 HP TEFC motor drawing 8 amps.
-