WARNING
Keep hands away from the pinch point between the top front edge of the case and Top Tapehead Holder.
Sharp cutter knives are in each tape head. Use caution whenever re‐threading tape or handling the heads.
Lockout electrical power before adjusting or servicing.
Machine Overview
Starting the Machine
The DEKKA 100 has a power switch fitted with a trip and lockout function. This is to ensure operator safety and motor protection. The trip function is activated when the motor is overloaded, such as whenthere is a severe case jam.
To reset a tripped switch, turn the power switch to the:
1. OFF position, then the
2. ON position.
Feeding Cases
- Turn ON your machine.
- After the case is filled, fold down the top flaps of the case by hand.
- Hold the top flaps closed and direct the case between the case width guides until the case is gripped by the conveyor belts.
The belts grip the case and transport it through the tape heads that tape the top and bottom flaps.
Thank you for contacting us. For us to better assist you, please reach out to our technical support by phone at 1.888.565.3219 or 604.930.9300 or by email at Wexxar.Service@promachbuilt.com or Wexxar.Parts@promachbuilt.com along with your machine model and serial number. One of our tech support reps will be glad to answer any questions you may have.